INTEGRATED OIL & GAS PACKAGES

5K Well Testing Package

5,000 psi nominal inlet pressure class surface well testing package, configured to the well and test program.

5K Well Testing PackageRepresentative separator photo; the complete package layout and equipment selection are project specific.
EQUIPMENT OVERVIEW

How 5K Well Testing Package works

A 5K surface well testing package brings together the equipment needed to control and measure the output of a well with a specified 5,000 psi high-pressure inlet class. Starting at the flowhead interface, the proposed arrangement passes through safety isolation, data and choke sections before heat conditioning where needed, test separation and downstream measurement or transfer. The test program determines whether gas, oil and water need individual metering, how liquids are stored or disposed of, and which utilities are available. The separator and downstream components are designed to their own operating and relief cases after the choke; they do not inherit the inlet rating. Battery limits and the item list are fixed in the approved offer.

PACKAGE CONFIGURATION

What a 5K surface well testing spread can include

A package can be supplied as individual skids or an integrated spread. The precise battery limits, equipment count and approved vendors are determined with the client; an item shown below is an available configuration, not an automatic inclusion.

Wellstream control

Surface test tree or flowhead interface, 5K class surface safety valve, data header, choke manifold and ESD logic where specified. Sand filtration or desanding can be incorporated for solids-bearing flowback.

Process and measurement

Indirect heating when needed, a two- or three-phase test separator, level and pressure control and oil, gas and water measurement selected for the expected range and fluid properties.

Transfer and utilities

Surge or gauge tank, liquid transfer pumps, diverter manifolds, burner or flare interface, data acquisition, instrument air and power connection are scoped to the test plan and site facilities.

ENGINEERING BOUNDARIES

Pressure class, ratings and project documents

For a 5K design, identify the 5,000 psi inlet-class items on the P&ID and trace the pressure boundary through the safety valve and choke. Rate the downstream heater, separator, meter runs and tanks independently for their governing cases, including possible blocked outlet and relief scenarios. The offer should set out connection types, skid interfaces, individual vessel ratings, test documentation and scope exclusions. Send the flowing pressure range, expected flow profile, oil/gas/water rates and disposal arrangement so the chosen equipment matches the test objectives.

APPLICATION & CONFIGURATION

Developed for the operating duty

Typical applications

  • Exploration and appraisal well tests
  • Flowback, clean-up and production test campaigns
  • Mobile or skid-mounted packages where transport limits permit

Inputs for engineering

  • Maximum and minimum wellhead pressure, flowing temperature and expected rates
  • Oil, gas, water, sand and potential sour-service composition
  • Test duration, metering accuracy, disposal route and hazardous-area classification
  • Client pressure class, design code, site utilities and transport envelope
POTENTIAL SUPPLY SCOPE

What the package can include

  • High-pressure inlet: surface test tree or flowhead interface, surface safety valve, data header and choke manifold as specified
  • Optional sand handling: sand filter or desander and associated isolation/drain arrangement
  • Conditioning: indirect heater or process heat exchanger if required by fluid and temperature
  • Separation: two- or three-phase test separator with controls and specified oil, gas and water metering
  • Liquid handling: surge/gauge tank, transfer pumps and oil/water diverter manifold to disposal or storage
  • Gas and disposal: burner or flare interface subject to site permits and client scope
  • Controls and utilities: ESD panel, field instruments, data acquisition, instrument air and power interfaces
  • Deliverables: process and instrumentation diagram, general arrangement, equipment datasheets, inspection and test records

Final sizes, material grades, pressure classes, makes, testing and documentation are specified in the approved technical offer. We coordinate applicable design, fabrication, inspection and quality records against the project requirements.

TECHNICAL QUESTION

Is every vessel in a 5K well testing package rated 5,000 psi?

No. The 5K designation identifies the agreed high-pressure inlet class. The separator, heater, tank and downstream piping are designed against their own governing pressures after the choke.

TALK TO OUR ENGINEERING TEAM

Request a technical offer

Share your duty and package requirements. We will review them and reply to the email you provide.

For complex enquiries, include the design pressure, temperature, flow, fluid composition, scope and delivery location.

Fields marked * are required. Send confidential project documents through an agreed email channel.